Mfgrs.Of Online UPS System, Computer Support System, Sinewave Inverters, Chargers, CVT & Ultra Isolation Transformerst

Content on this page requires a newer version of Adobe Flash Player.

Get Adobe Flash player

 

On-Line UPS

 
On-Line UPS

UPS system today has come a long way from the type it was introduced in 80s. Technological Developments have brought newer and better concepts in the field. The latest trend is that of PWM technology using IGBT. ‘ASEEM-OORJA’ has incorporated advanced technology in the field. Micro Controller is used to control the processes such as pure Sine Wave generation, Alarms and Indications, Shut Down characteristics and protections.

Starting from 1 KVA to 30KVA single phase output systems and 10KVA to 500KVA 3 phase output systems are available.

The after Sales Service is our strong feature. We believe that Good Service retains customers and that Customer Retained is Customer Gained.

 

Get the "ASEEM-OORJA"® Advantage

ASEEM-OORJA® the trusted brand of the an iso certified company in the field of UPS since 1990s. Unmatched performance, with latest technology gives you a superior edge against vagaries of power. Best known UPS for critical load application, “ASEEM-OORJA” ®Is also known for prompt after sales service.

 
TECHNICAL SPECIFICATIONS
 

TECHNOLOGY

SINE PWM WITH IGBT & LCD/LED DISPLAY

CAPACITIES

2 KVA TO 30 KVA WITH BUILT-IN ISOLATION

I

N

P

U

T

WINDOW

170VAC-270VAC (1PH), 300-460VAC (3PH)

DC BUS

48VDC TO 360VDC

EFFICIENCY

BETTER THAN 85% AC-IN-AC-OUT

INTERFACE

AUTO SHUT DOWN SOFTWARE. [SNMP INTERFACE OPTIONAL]

O

U

T

P

U

T

VOLTAGE

230VAC ± 1%, 50Hz ± 0·1% (CRYSTAL CONTROLLED)

OUTPUT P/F

0·8 LAGGING TO UNITY

TRANSIENT RESPONSE

O/P OVERSHOOT & UNDERSHOOT LESS THAN 5% @100% LOAD CHANGE.

DISTORTION

LESS THAN 2% FOR LINEAR LOAD & LESS THAN 5% FOR NON LINEAR LOAD

CREST FACTOR

4:1

WAVEFORM

PURE SINE WAVE

INVERTER EFFICIENCY

BETTER THAN 90%

GENSET COMPATIBILITY

COMPATIBLE TO GENSET OF ANY MAKE

PROTECTIONS

1. O/P OVERLOAD, 2. O/P SHORT CKT, 3. O/P OVER VOLTAGE, 4. BATTERY LOW

COOLING

FORCED AIR COOLING

INDICATIONS

1. MAINS/CHARGER ON, 2. INV ON, 3. SYSTEM OVERLOAD, 4. BATTERY LOW

WORKING CONDITIONS

0 TO 45°C, HUMIDITY 95%RH ( NON-CONDENSING)

 
Salient features
State of an art design

Wide input window

Latest IGBT Technology

Isolated O/P

Pure Sine wave O/P

User friendly Design

High MTBF

RS232 interface & SNMP Optional  

 
 
 
On-Line UPS    |    Modular UPS    |    Sinewave Inverter    |    Constant Voltage Transformer ( C V T )     |    Ultra Isolation Transformer   |
Servo Controlled Voltage Stabilizer    |    Transformer
 
 
Home   |   Profile    |    Products     |   Clients     |    E-catalogue     |    Contact      |     Enquiry
Designed & Hosted by : MID   Promoted by : GID